All UDS services

ECU Reset

0x11

The ECU Reset service used by the client to request that the server perform a reset of the ECU. The server performs the specified type of reset after sending the positive response.

Negative response codes
0x120x130x220x33

Request

SID 0x11 · 2 bytes
Len (bits)
Parameter description
Value (hex)
8
ECU Reset SID
0x11
1
suppressPosRspMsgIndicationBitBit 7 of the sub-function byte. If set to 1, the server shall not send a positive response message.
7
resetTypeSub-function parameter that defines the type of reset to be performed by the server.

Positive response

SID 0x51
Len (bits)
Parameter description
Value (hex)
8
ECU Reset SID
0x51
1
Echo of suppressPosRspMsgIndicationBit
7
Echo of resetType
8
powerDownTimeTime (in seconds) the server requires to complete the power down sequence. Only present when resetType is enableRapidPowerShutDown (0x04). Value 0xFF means the time is not available.Optional
0x00-0xFF