Input Output Control By Identifier
0x2FThe Input Output Control By Identifier service allows the client to control input/output signals of the server by specifying a Data Identifier and a control action.
✕Negative response codes
0x130x220x310x33
Request
SID 0x2F · 4 bytesLen (bits)
Parameter description
Value (hex)
8
Input Output Control By Identifier SID0x2F16
dataIdentifierTwo-byte identifier of the I/O function to control.0x0000-0xFFFF8
Hands back control of the I/O function to the ECU.
0x00n = Number of control state bytes
m = Number of control enable mask bytes
Positive response
SID 0x6FLen (bits)
Parameter description
Value (hex)
8
Input Output Control By Identifier SID0x6F16
Echo of
dataIdentifier0x0000-0xFFFF8
Hands back control of the I/O function to the ECU.
0x00n*
8
controlStateCurrent state of the controlled I/O function.0x00-0xFFn = Number of control state bytes