All UDS services

Link Control

0x87

The Link Control service allows the client to verify and switch the communication link baudrate between the client and the server.

Negative response codes
0x120x130x220x240x31

Request

SID 0x87 · 2 bytes
Len (bits)
Parameter description
Value (hex)
8
Link Control SID
0x87
1
suppressPosRspMsgIndicationBitBit 7 of the sub-function byte. When set to 1, the server will not send a positive response.
7
Verifies the server can transition to a standard baudrate from a predefined list.
0x01
8
linkControlModeIdentifier

Positive response

SID 0xC7
Len (bits)
Parameter description
Value (hex)
8
Link Control SID
0xC7
1
Echo of suppressPosRspMsgIndicationBit
7
Verifies the server can transition to a standard baudrate from a predefined list.
0x01